Please use this identifier to cite or link to this item:
http://localhost:8080/xmlui/handle/123456789/3724| Title: | Bi-Directional Clamping Based H5, HERIC and H6-Type Transformerless Inverter Topologies with Improved Modulation Technique |
| Authors: | Kumar, K. Sateesh Kirubakaran, A. Subrahmanyam, N. |
| Keywords: | Common mode voltage Leakage current |
| Issue Date: | 2020 |
| Publisher: | 2020 IEEE International Conference on Power Electronics, Smart Grid and Renewable Energy, PESGRE 2020 |
| Citation: | 10.1109/PESGRE45664.2020.9070590 |
| Abstract: | Transformerless inverters (TLIs) are well commercialized for Photovoltaic applications due to its small in size, less cost and high power conversion efficiency. However, the major challenge is to develop an inverter with reactive power capability and minimum leakage current. Therefore, in this paper, an improved H5, Heric, and H6-type topologies with bi-directional clamping branch are proposed to maintain constant common-mode voltage (CMV) during the freewheeling period. Thus, high-frequency variations due to switch junction capacitances in CMV are diminished and it further reduces the leakage current. Besides, an improved pulse width modulation scheme (PWM) provides a bi directional current path during zero state to enhance the output waveform quality of the grid-connected inverter at different power factor conditions. Finally, the proposed concept is examined through the simulation results using Matlab software. |
| Description: | NITW |
| URI: | http://localhost:8080/xmlui/handle/123456789/3724 |
| Appears in Collections: | Electrical Engineering |