Title: | Polymer-coated fiber Bragg Grating Sensor for cryogenic temperature measurements |
Authors: | Parne, S. Sai Prasad, R.L.N. Dipankar, S.G. Sai Shankar, M. Kamineni, S. |
Keywords: | Polymer-coated fiber Bragg Cryogenic temperature |
Issue Date: | 2011 |
Publisher: | Microwave and Optical Technology Letters |
Citation: | 10.1002/mop.25914 |
Abstract: | Cryogenic temperature sensing has been demonstrated using Polymer coated Fiber Bragg Grating Sensor, and the experimental results are presented in this article. Teflon coating thicknesses of 20 and 40 μ applied on Fiber Bragg Gratings, inscribed in silica fiber (TFBG) are used for these studies. It was observed that the sensitivity of Teflon‐coated FBG has been enhanced three times compared to uncoated regular FBGs |