dc.description.abstractA simple technique to discriminate the Strain and Temperature with a single Fiber Bragg Grating (FBG) at cryogenic regime is presented in this paper. An uniform FBG is divided into two parts, one half is without coating (FBG1) and other half is coated with Cyno-Acrylic Adhesive (FBG2). The measured temperature and strain sensitivities of the FBG1 are 4.05×10−6/K and 2.13×10−6/µε and FBG2 are 1.39×10−5/K and 1.72×10−6/µε respectively.en_US
dc.language.isoenen_US
dc.publisher2011 Asia Communications and Photonics Conference and Exhibition (ACP)en_US
dc.subjectFBGen_US
dc.subjectCryogenicen_US
dc.subjectStrain temperature discriminationen_US
dc.subjectCoatingen_US
dc.titleAn FBG sensor for strain and temperature discrimination at cryogenic regimeen_US