Title: Comparison of control methods for high frequency IH cooking applications
Authors: Bhaskar, D.V.
Yagnyaseni, N
Maity, T.
Vishwanathan, N
Keywords: Induction Heating
Phase shift control method
Issue Date: 2014
Publisher: 2014 Power and Energy Systems Conference: Towards Sustainable Energy, PESTSE 2014
Citation: 10.1109/PESTSE.2014.6805272
Abstract: This paper presents the comparison of different fixed frequency control strategies for Induction Heating (IH) applications. Phase shift control method (PSM), Asymmetrical duty cycle control (ADC) method, and Asymmetrical voltage cancellation (AVC) methods are used to control the output voltage in IH applications. The performance analysis of the control methods is discussed in this paper. The MATLAB simulation results are given to validate the control schemes.
Description: NITW
URI: http://localhost:8080/xmlui/handle/123456789/2389
Appears in Collections:Electrical Engineering

Files in This Item:
File Description SizeFormat 
Comparison of control methods for high frequency IH cooking applications.pdf1.38 MBAdobe PDFView/Open