Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/2112
Title: Hardware Implementation of Direct Load AngleControlled Induction Motor Drive
Authors: Kumar, Thippiripati Vinay
Rao, Sandepudi Srinivasa
Keywords: AC drive,
Direct load angle control
Direct flux control
Dynamic response
Induction motor drive
Issue Date: 2014
Publisher: Electric Power Components and Systems
Abstract: In this article, a direct load angle (DLA) control method for induction motor drive is proposed to reduce the torque and flux ripple. It is based on control of incremental change in load angle. The torque control is achieved without losing the benefits of conventional direct torque control (DTC) by reference stator flux angle, which is the sum of load angle and rotor flux angle. In this proposed DTC scheme, coordinate transformation is not required in torque control unit and reference voltage sector number and angle are not required in PWM unit, which reduces the control complexity. Proposed DTC control method is applied to two level voltage source inverter fed induction motor drive and hardware results are presented. From the hardware results, it is found that the proposed DTC control scheme impressively reduces the torque and flux ripples when compared with conventional space vector modulation (SVM) DTC.
Description: NITW
URI: http://localhost:8080/xmlui/handle/123456789/2112
Appears in Collections:Electrical Engineering

Files in This Item: