Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/1709
Title: Development and Validation of a Liquid Chromatographic Method for Monitoring of Process-Related Synthetic Organic Impurities of Profenofos in Technical Products
Authors: Rao, R.N.
Raju, D.N.
Venkateswarlu, N.
Rao, B.V.
Parvathi, N.
Manjula, A.
Reddy, G.N.
Gawali, P.B.
Sreekanth ., M
Rao, P.N.
Keywords: Liquid Chromatographic
Synthetic Organic Impurities
Profenofos
Technical Products
Issue Date: 2003
Publisher: Journal of Chromatographic Science
Citation: 10.1093/chromsci/41.8.418
Abstract: A simple and rapid reversed-phase high-performance liquid chromatographic method for the monitoring of process-related synthetic organic impurities of profenofos (PFS) is developed. Impurities are separated and determined on a reversed-phase Hypersil C18 column using gradient elution of 50mM ammonium formate buffer-acetonitrile as a mobile phase and detection at 230 nm at ambient temperature. The method is validated with respect to accuracy, precision, linearity, and limits of detection and quantitation. The method is found to be suitable not only for monitoring the reactions involved in the process development of PFS, but also quality assurance, as it can detect impurities at the level of 1.5 × 10−8 g.
Description: NITW
URI: http://localhost:8080/xmlui/handle/123456789/1709
Appears in Collections:Chemistry

Files in This Item:
File Description SizeFormat 
41-8-418.pdf148.58 kBAdobe PDFView/Open